Power Devices

You can integrate following measuring devices. For more information Power Devices, refer to the Power Devices’ manual.

PAC1200

The PAC1200 multi-channel current-measuring system supplements the product range of the power monitoring system. It provides a low-cost solution for the transparent representation of energy consumption and also enables the resulting costs to be displayed. The current values themselves are measured by means of sensors that are fitted above the miniature circuit breakers. The simple cost center allocation enables maximum transparency over the entire application.

The PAC1200 multi-channel current-measuring system monitors and displays the energy consumption of up to 96 outgoing feeders. You can configure 12 sensor bars for a maximum number of 8 times (always 8 bars with the respective combination). Up to eight different selectable consumption sources can be compared with each other. The system can be scaled to individual needs and application scenarios. The individual sensors can be named individually and compared with each other. The system can be configured flexibly as the number of sensor bars can vary.

Generic Features of the Device

Feature

Applicable

Digital Inputs

No

Digital Outputs

No

Counters

Yes

Synchronization

No

Event Memory

No

Power Period

No

Power Quality

No

N conductor

No

Password

No

TCP

Yes

RTU

No

Web page

Yes

 

  • Features specific to the device: You can physically add or remove sensors from a PAC1200 controller. You can use the update function to replicate these changes in the Powermanager tree.

 

PAC1600

The PAC1600 is a family of E-counters for measuring consumption values in three-phase systems. This unit registers exported or imported energy and it stores active and reactive energy. It is a measuring device for measuring the basic electrical variables in low voltage power distribution. Measured variables are shown on the display of the PAC1600.

The PAC1600 is mounted on a DIN rail or is screwed in place using extractable clips.

The following variants are available for PAC1600:
PAC1651
PAC1652
PAC1661
PAC1662
PAC1665
PAC1666
PAC1682

 

Generic Features of the Device (PAC16XX)

Feature

Applicable

Digital Inputs

No

Digital Outputs

No

Counters

Yes

Synchronization

No

Event Memory

No

Power Period

No

Power Quality

No

N conductor

No

Password

No

TCP

No

RTU

Yes

Web page

No

PAC2200

The PAC2200 is a power monitoring device for displaying all the relevant line parameters. It collects all the basic measured variables and the extended measured variables (for example, THD). Limit values are available for line monitoring. It performs single-phase, two-phase, or three-phase measurement and can be used in two-wire, three-wire, or four-wire TN, TT, and IT systems. The PAC2200 with multi-range power supply can thus be connected directly to every low-voltage system up to a line voltage of 690 V.

Connect PAC2200 power monitoring device to powermanager through the integral Ethernet interface using Modbus TCP.
NOTE: Reset of energy counters are not supported for firmware version 3.2.2 and above.

Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

No

N conductor

No

Password

Yes

TCP

Yes

RTU

Yes

Web page

Yes

PAC2200CLP

The PAC2200CLP (Certified Load Profile) is a power monitoring device for measuring, monitoring, calculating, displaying and archiving all the relevant line parameters. It collects all the basic measured variables. Limit values are available for line monitoring. It is integrated with quarter hour load profile with a memory depth for billing all relevant data. It performs single-phase, two-phase, or three-phase measurement and can be used in two-wire, three-wire, or four-wire TN, TT, and IT systems. The PAC2200CLP with multi-range power supply can thus be connected directly to every low-voltage system up to a line voltage of 690 V.

Connect PAC2200CLP power monitoring device to powermanager through the integral Ethernet interface using Modbus TCP.

Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

Yes

Power Period

Yes

Power Quality

No

N conductor

No

Password

Yes

TCP

Yes

RTU

No

Web page

Yes

 

Counters and average power demand values

  • Recording of active, reactive and apparent energy by means of several energy counters.
  • Calculation and storage of the last demand period average value for active and reactive power for simple software-driven generation of load profiles.
  • Calculation of average values for active and reactive power of the last completed demand period for import and export.
  • Time stamp of the current demand period acc. to ISO8601 (local and UTC time).
  • MID-certified active energy counter for import and export (Measuring Instruments Directive 2014/32/EU).
  • With load profile measurement conforming to statutory calibration regulations and national approval according to PTB-A 50.7.
  • Integrated 15-minute load profile memory with a storage depth for all billing-relevant data over 2 years.
  • Integrated 15-minute load profile memory with a storage depth for all billing-relevant data over 2 years.

Features Specific to the Device:

  • PAC2200CLP Device also supports the Field System Alarm. The events from PAC2200CLP is sent to powermanager as field alarm. The classes of alarm is medium.
    • When the alarm is displayed in the Events tab, an option to acknowledge the alarm is provided along with the event and the source status, and once the user acknowledges the alarm, it will be removed from the event list. None of the events will be removed from the device and remain in the device memory.

 

PAC3100

The PAC3100 is a power monitoring device for displaying basic electrical variables and energy acquisition values (counters) in low-voltage power distribution. It performs single-phase, two-phase, and three-phase measurement and can be used in three-wire or four-wire TN, TT, and IT systems.

The minimum supported firmware version for PAC3100 is 1.0. You can use the gateway functionality of the PAC4200 to connect the device to powermanager. You can also use any Modbus gateway to establish the connection.

With the help of the basic measured variables (for example, voltage, currents, energy values), extensive evaluations can already be undertaken in the powermanager.

Generic Features of the Device

Feature

Applicable

Digital Inputs

No

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

No

N conductor

No

Password

Yes

TCP

No

RTU

Yes

Web page

No

PAC3120

The PAC3120 is a power monitoring device for displaying basic electrical variables and energy acquisition values (counters) in low-voltage power distribution. It performs single-phase, two-phase, and three-phase measurement and can be used in three-wire or four-wire TN, TT, and IT systems.

The minimum supported firmware version for PAC3120 is 1.0. You can use the gateway functionality of the PAC4200 to connect the device to powermanager. You can also use any Modbus gateway to establish the connection.

The device menu contains the Hardware write protection command. If the write protection is activated, no parameter can be written by powermanager:

  • General Write protection
  • Protection of display settings
  • Protection of extrema min/max values
  • Protection of communication settings
  • Protection of password settings
  • Protection of time settings
  • Protection of limit settings

PAC3120 has a device LED that can be set to active or inactive state. It can used to indicate the following:

  • Off
  • Device ON
  • Remote
  • Rotation
  • Limit Violation
  • Pulse Output
  • Remote Color
  • Digital Input State
Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

Yes

N conductor

No

Password

Yes

TCP

No

RTU

Yes

Web page

No

 

  • Features specific to the device: Cos phi data point is supported for devices with firmware version 3.1.4 and above.
PAC3200

The PAC3200 is a power monitoring device for displaying all the relevant line parameters. It collects all the basic measured variables and the extended measured variables (for example, THD). Limit values are available for line monitoring. It performs single-phase, two-phase, or three-phase measurement and can be used in two-wire, three-wire, or four-wire TN, TT, and IT systems. PAC3200 with multi-range power supply can thus be connected direct in every low-voltage system up to a line voltage of 690 V.

Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

Yes

N conductor

Yes

Password

Yes

TCP

Yes

RTU

Yes

Web page

No

PAC3220

The PAC3220 is a power monitoring device for displaying all the relevant line parameters. It collects all the basic measured variables and the extended measured variables (for example, THD). Limit values are available for line monitoring. It performs single-phase, two-phase, or three-phase measurement and can be used in two-wire, three-wire, or four-wire TN, TT, and IT systems. PAC3220 with multi-range power supply can thus be connected direct in every low-voltage system up to a line voltage of 690 V.

The device menu contains the Hardware write protection command. If the write protection is activated, no parameter can be written by powermanager:

  • General Write protection
  • Protection of display settings
  • Protection of extrema min/max values
  • Protection of communication settings
  • Protection of password settings
  • Protection of time settings
  • Protection of limit settings

PAC3220 has a device LED that can be set to active or inactive state. It can used to indicate the following:

  • Off
  • Device ON
  • Remote
  • Rotation
  • Limit Violation
  • Pulse Output
  • Remote Color
  • Digital Input State
Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

Yes

N conductor

Yes

Password

Yes

TCP

Yes

RTU

No

Web page

Yes

 

  • Features specific to the device: Cos phi data point is supported for devices with firmware version 3.1.4 and above.

 

PAC3200T

The 7KM PAC3200T is a power monitoring device for displaying all the relevant line parameters. It collects all the basic measured variables and the extended measured variables (for example, THD). Limiting values are available for line monitoring. The PAC3200T performs 1-phase, 2-phase, or 3-phase measurement and can be used in 2-wire, 3-wire, or 4-wire TN, TT, and IT systems. The PAC3200T with multi-range power supply can thus be connected directly in every low-voltage system up to a line voltage of 690 V.

Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

No

Power Period

Yes

Power Quality

Yes

N conductor

No

Password

Yes

TCP

Yes

RTU

No

Web page

Yes

PAC4200
  • PAC4200 is a power monitoring device for displaying, storing, and monitoring all relevant line parameters in low-voltage power distribution. Compared to PAC3200, the PAC4200 has extended measuring functions (> 800 measured variables), an integral memory for buffering the load profile and events, as well as, gateway functionality. It performs single-phase, two-phase, or three-phase measurement and can be used in two-wire, three-wire, or four-wire TN, TT, and IT systems.
  • The minimum (>2000) supported firmware version for PAC4200 is V1.5. Connect the PAC4200 power monitoring device to powermanager through the integral Ethernet interface using Modbus TCP.
Generic Features of the Device

Feature

Applicable

Digital Inputs

Yes

Digital Outputs

Yes

Counters

Yes

Synchronization

Yes

Event Memory

Yes

Power Period

Yes

Power Quality

Yes

N conductor

Yes

Password

Yes

TCP

Yes

RTU

Yes

Web page

No

 

  • Features Specific to the Device:
  • PAC4200 Device also supports the Field System Alarm. The two classes of alarms supported by powermanager are High and Low. For a StatusFixedAlarm property which is configured for a device in the Engineering mode, the field system alarms of the class High and Low are displayed and monitored in the Events tab of the Powermanager application. PAC4200 device supports up to 4096 events, the type of events supported are listed below:
    • Operating Information
    • System Information
    • Operation
    • When the alarm is displayed in the Events tab, an option to acknowledge the alarm is provided along with the event and the source status.

 

On creation of PAC4200 with firmware version 2.0 or higher project has to be restarted to poll maximum harmonics values.

For PAC4200 devices once the type of use configuration of any digital output is changed in the device, powermanager might take at least 5 minutes to update the type of use in Control tile Digital output section of respective devices.

 

SEM3

The Siemens Embedded Micro Metering Module (SEM3) is a modular metering solution for energy monitoring, data analysis, and sub billing applications. The flexible design allows for low, medium, and high density metering requirements to be met efficiently and economically using only a few standardized components integrated into Siemens Panel board and Switchboard products.

The SEM3 system is made up of the following components and options:

  • Controller
  • Meter modules
  • Meter racks
  • Current transformers (CT)
  • Communication cables
Generic Features of the Device

Feature

Applicable

Digital Inputs

No

Digital Outputs

No

Counters

Yes

Synchronization

No

Event Memory

No

Power Period

Yes

Power Quality

No

N conductor

No

Password

Yes

TCP

Yes

RTU

Yes

Web page

Yes

 

  • Features specific to the device: You can physically add or remove sensors from a SEM3 controller. You can use the update function to replicate these changes in the Powermanager tree.

 

 

All counter and power period calculations are delayed by fifteen seconds.

Load management is possible using Reactions. You can configure conditions based on requirements where you can turn ON or OFF loads, through breaker ON or OFF using digital output of PAC meters.